KMDA7676FL-U, KMDA7876FL-U - surface installation, drilling template, 23,8 cm, Installation drawing
KMDA 7676 FL-U BlackPerfectionInduction hob with integrated vapour extraction with two extra large PowerFlex XL cooking areas for recirculation mode
More product information
Induction hob with integrated vapour extraction with two extra large PowerFlex XL cooking areas for recirculation mode
- The quietest TwoInOne from Miele – Silence motor
Silence motor
Extra-quiet: developed by Miele, this motor is 25 % quieter than its predecessor at higher air throughput levels. - Flexible installation – ducted recirculation (e.g. with DFKS-UR) or Plug & Play
- Ample space – 4 large cooking zones incl. 2 PowerFlex XL areas
PowerFlex XL
Ample space: as the entire depth of the hob can be used, large cookware can be positioned perfectly. - Automatic fan power regulation – Con@ctivity
Con@ctivity
Innovative convenience: the cooker hood reacts automatically to settings on the hob. - All-black design ensures an elegant appearance
Downloads - KMDA 7676 FL-U BlackPerfection
User manual & Assembly
CAD data / BIM data
Installation drawings
KMDA7676FL, KMDA7876FL - flush - Installation drawing
1) Front, 2) removable drip tray, 3) cleaning flap, 4) Mains connection box with mains connection cable, L = 1600 mm, 5) Step milling natural stone worktop, 6) Wooden strip 12 mm (not included in delivery), 7) Worktop thickness, Exhaust air and guided recirculation mode: ≥10 mm, Plug&play operation: ≥10 mm - ≤40 mm
KMDA7676FL, KMDA7876FL - Side view lying on top - Installation drawing
①The rear wall of the cabinet must be removable for servicing. A minimum distance of 110 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ②The removable collection tray and the cleaning flap must be accessible after installation.
KMDA7676FL, KMDA7876FL - Side view flush+X, Plug&Play - Installation drawing
①A minimum distance of 25 mm must be maintained for routing the exhaust air duct between the carcase wall and an adjacent room wall or furniture. If the carcase rear wall is
KMDA7676FL, KMDA7876FL - Installation variant 2 Basis - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90
KMDA7676FL, KMDA7876FL - Installation variant 5 Circulating air - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90, 5) DFK-V, 6) DUU 1500, , The minimum depth of the cabinet is 935 mm.
KMDA7676FL, KMDA7876FL - Installation variant 14 Circulating air - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90, 5) DFK-V, 6) DUU 1500, , The minimum width of the cabinet is 900 mm.
KMDA7676FL/FR, KMDA7876FL/FR, Plug&Play (Installation drawing)
KMDA7676FL-U BlackPerfection, KMDA7876FL-U - flush installation, drilling template, Installation depth 23,8 cm
KMDA7676FL-U, KMDA7876FL-U - flush installation, drilling template, Installation depth 24,8 cm, Installation drawing
KMDA7676FL, KMDA7876FL - Side view lying on top, Plug&Play - Installation drawing
①A minimum distance of 25 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ②The removable collection tray and the cleaning flap must be accessible after installation., ③The cross-section of the vent opening must be at least 425 cm².
KMDA7676FL/FR, KMDA7876FL/FR, Air circulation (Installation drawing)
KMDA7676FL, KMDA7876FL - Side view flush - Installation drawing
①The rear wall of the cabinet must be removable for servicing. A minimum distance of 110 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ②The removable collection tray and the cleaning flap must be accessible after installation.
KMDA7676FL, KMDA7876FL - Side view flush, Plug&Play - Installation drawing
①A minimum distance of 25 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ②The removable collection tray and the cleaning flap must be accessible after installation., ③The cross-section of the ventilation opening must be at least 425 cm².
KMDA7676FL, KMDA7876FL - Installation variant 4 Circulating air - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90, 5) DFK-V, 6) DUU 1500, , The minimum width of the cabinet is 1350 mm.
KMDA7676FL, KMDA7876FL - Installation variant 6 Circulating air - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-V, 5) DUU 1500, , The minimum depth of the cabinet is 935 mm.
KMDA7676FL, KMDA7876FL - Installation variant 13 Circulating air - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90, 5) DFK-V, 6) DUU 1500, , The minimum width of the cabinet is 1125 mm.
KMDA7676FL-U, KMDA7876FL-U - surface installation, 24,8 cm, drilling template, Installation drawing
KMDA7676FL, KMDA7876FL - Installation drawing
1) Front, 2) Removable drip tray, 3) Cleaning flap, 4) Mains connection box with mains connection cable, L = 1600 mm, 5) Worktop thickness, Exhaust air and guided recirculation mode: ≥10 mm, Plug&Play operation: ≥10 mm - ≤40 mm
KMDA7676FL, KMDA7876FL - Side view lying on top+X - Installation drawing
①The rear wall of the cabinet must be removable for servicing. A minimum distance of 110 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ② The removable collection tray and the cleaning flap must be accessible after installation., , x Dimension by which the worktop depth is greater than 600 mm.
KMDA7676FL, KMDA7876FL - Side view flush+X - Installation drawing
①The rear wall of the cabinet must be removable for servicing. A minimum distance of 110 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ②The removable collection tray and the cleaning flap must be accessible after installation., , x Dimension by which the worktop depth is greater than 600 mm.
KMDA7676FL, KMDA7876FL - Side view lying on top+X, Plug&Play - Installation drawing
①A minimum distance of 25 mm must be maintained for routing the exhaust air duct between the carcase wall and an adjacent room wall or furniture. If the carcase rear wall is
KMDA7676FL, KMDA7876FL - Installation variant 1 Basis -drawing
1) DFK-AK 90, 2) DFK-R 1000
KMDA7676FL, KMDA7876FL -Installation variant 3 Basis - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90