KMDA7272FL/FR, KMDA7473FL/FR - surface installation, drilling template, Installation drawing
KMDA 7473 FL-U SilenceInduction hob with integrated vapour extraction with Silence motor and 2 Flex zones for recirculation mode
More product information
Induction hob with integrated vapour extraction with Silence motor and 2 Flex zones for recirculation mode
- The quietest TwoInOne from Miele – Silence motor
Silence motor
Extra-quiet: developed by Miele, this motor is 25 % quieter than its predecessor at higher air throughput levels. - Flexible installation – ducted recirculation (e.g. with DFKS-UR) or Plug & Play
- Ample space – 4 large cooking zones incl. 2 Flex zones
FlexZone
Unique space provision: the Miele FlexZones allow you to position large pots and pans behind each other. - Automatic fan power regulation – Con@ctivity
Con@ctivity
Innovative convenience: the cooker hood reacts automatically to settings on the hob. - Compact control using the numerical display – ComfortSelect Plus
ComfortSelect Plus
Compact and convenient: all cooking zones and the fan can be operated using a clear central numerical display.
Downloads - KMDA 7473 FL-U Silence
User manual & Assembly
CAD data / BIM data
Installation drawings
KMDA7272FL, KMDA7473FL - flush installation, drilling template, Installation depth 20 cm, Installation drawing
KMDA7473FL/FR - Operating options
✓✓ Possible, ✓ Possible - further accessories necessary, - Programming must be changed - further accessories necessary
KMDA7272FL/FR, KMDA7473FL/FR - Installation variant 2 Basis - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90
KMDA7272FL, KMDA7473FL - Side view flush+X, Plug&Play - Installation drawing
①A minimum distance of 25 mm must be maintained for routing the exhaust air duct between the carcase wall and an adjacent room wall or furniture. If the carcase rear wall is
KMDA7272FL, KMDA7473FL - Side view lying on top+X, Plug&Play - Installation drawing
①A minimum distance of 25 mm must be maintained for routing the exhaust air duct between the carcase wall and an adjacent room wall or furniture. If the carcase rear wall is
KMDA7272FL, KMDA7473FL - flush installation, drilling template, Installation depth 21 cm, Installation drawing
KMDA7272FL/FR, KMDA7473FL/FR - Installation variant 1 Basis -drawing
1) DFK-AK 90, 2) DFK-R 1000
KMDA7272FL/FR, KMDA7473FL/FR - Installation variant 14 Circulating air - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90, 5) DFK-V, 6) DUU 1500, , The minimum width of the cabinet is 900 mm.
KMDA7272FL, KMDA7473FL - flush - Installation drawing
1) Front, 2) removable drip tray, 3) cleaning flap, 4) Mains connection box with mains connection cable, L = 1600 mm, 5) Step milling natural stone worktop, 6) Wooden strip 12 mm (not included in delivery), 7) Worktop thickness, Exhaust air and guided recirculation mode: ≥10 mm, Plug&play operation: ≥10 mm - ≤40 mm
KMDA7272FL/FR, KMDA7473FL/FR, Air circulation (Installation drawing)
KMDA7272FL/FR, KMDA7473FL/FR - Installation variant 13 Circulating air - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90, 5) DFK-V, 6) DUU 1500, , The minimum width of the cabinet is 1125 mm.
KMDA7272FL, KMDA7473FL - Installation drawing
1) Front, 2) Removable drip tray, 3) Cleaning flap, 4) Mains connection box with mains connection cable, L = 1600 mm, 5) Worktop thickness, Exhaust air and guided recirculation mode: ≥10 mm, Plug&Play operation: ≥10 mm - ≤40 mm
KMDA7272FL/FR, KMDA7473FL/FR, Plug&Play (Installation drawing)
KMDA7272FL, KMDA7473FL - Side view flush, Plug&Play - Installation drawing
①A minimum distance of 25 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ②The removable collection tray and the cleaning flap must be accessible after installation., ③The cross-section of the ventilation opening must be at least 425 cm².
KMDA7272FL, KMDA7473FL - Side view lying on top, Plug&Play - Installation drawing
①A minimum distance of 25 mm must be maintained for routing the exhaust air duct between the cabinet wall and an adjacent room wall or furniture., ②The removable collection tray and the cleaning flap must be accessible after installation., ③The cross-section of the vent opening must be at least 425 cm².
KMDA7272FL/FR, KMDA7473FL/FR - surface installation, 21 cm, drilling template, Installation drawing
KMDA7272FL/FR, KMDA7473FL/FR - Installation variant 6 Circulating air - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-V, 5) DUU 1500, , The minimum depth of the cabinet is 935 mm.
KMDA7272FL/FR, KMDA7473FL/FR - Installation variant 5 Circulating air - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90, 5) DFK-V, 6) DUU 1500, , The minimum width of the cabinet is 1350 mm.
KMDA7272FL/FR, KMDA7473FL/FR - Installation variant 4 Circulating air - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90, 5) DFK-V, 6) DUU 1500, , The minimum width of the cabinet is 1350 mm.
KMDA7272FL/FR, KMDA7473FL/FR -Installation variant 3 Basis - drawing
1) DFK-AK 90, 2) DFK-R 1000, 3) DFK-BV 90, 4) DFK-BH 90